The HDB corridor is one of the most familiar spaces in Singapore: the open walkway outside the front door, shared with neighbours, lined with shoe racks and potted plants, and used every day to reach the lift. It is also, by design, a fire escape route. That dual role, social space and life-safety element, explains why the rules about what residents can place there are stricter than many people expect.
This article explains how HDB corridors are designed, how fire safety requirements from the Singapore Civil Defence Force (SCDF) apply to them, what can and cannot be placed outside a flat, and who enforces the rules. It summarises published guidance from SCDF, HDB and Town Councils; the latest versions on their websites, and your own Town Council’s by-laws, take precedence.
How HDB corridors are designed
Many HDB blocks, particularly older slab blocks, are corridor-access buildings: a long, open-sided common corridor runs along one face of the block on each floor, with flats opening onto it and lifts and staircases at intervals. Point blocks and many newer designs instead cluster a small number of flats around a lift core, with shorter corridors or lobbies. The open corridor is a deliberately tropical solution. It is naturally ventilated, shaded by the floor above and allows breezes to pass through flats via windows and vents facing the walkway.
In older blocks, lifts often stopped only at certain floors, and residents walked along corridors and up or down stairs to reach their homes. HDB’s Lift Upgrading Programme has since added lift landings or new lifts to provide direct lift access on every floor where feasible, and the Ministry of National Development reported in 2024 that around 99 per cent of blocks now have direct lift access on every floor. The corridor’s role as the main route between flat, lift and staircase has remained.
Structurally, corridors are usually cantilevered or supported reinforced concrete slabs with a parapet wall along the open edge. The parapet is a safety barrier, not a shelf, which is one reason items should not be placed on or hung from it. Our article on parapet walls explains their structural role.
The corridor as a fire escape route
Under Singapore’s Fire Code, the common corridor forms part of the means of escape from each flat to the protected staircases. In a fire, residents must be able to leave their homes and move along the corridor quickly, in smoke and possibly in darkness, while firefighters move in the opposite direction with equipment. Anything that narrows the route or adds fuel to a fire undermines that design. For new buildings and significant fire safety works, compliance with the Fire Code is checked through SCDF’s plan approval and, on completion, the fire safety certificate; the corridor rules for residents exist to keep that approved escape route working over the building’s life.
The open-sided form helps: smoke and heat can disperse to the outside rather than accumulating in an enclosed passage. For the same reason, the Ministry of National Development has explained that the Fire Code requires fire-rated entrance doors for residential units except where a unit faces an external corridor that has been assessed to dissipate heat and smoke sufficiently, with exceptions such as units whose entrance doors are close to a lift lobby or staircase. Where a fire-rated entrance door is installed, HDB fits it with a self-closing door closer that must not be removed, so that a fire in the flat is contained and does not spill into the corridor. The general principles of fire-rated doors are covered in a separate article.
SCDF’s rules on corridor items
SCDF’s fire safety guidelines for residential estates allow some everyday items in common corridors, subject to conditions:
- Shoe racks are allowed for the sole purpose of keeping shoes, provided a minimum clear escape passage of 1.2 metres is maintained along the corridor, measured from the parapet wall to the rack.
- Clothing racks must be foldable or easily removable in an emergency so that they do not obstruct the escape route.
- Potted plants may be placed only if the Town Council or management corporation permits them, and the 1.2-metre unobstructed width must be maintained throughout the corridor.
- Staircases and their landings must be kept completely clear; no objects may be placed or stored there.
- Fire-fighting equipment: nothing may be stored in dry or wet riser compartments or hose reel compartments, and access to landing valves and breeching inlets must not be obstructed.
SCDF notes that the minimum clear width was increased from 1 metre to 1.2 metres following the revision of the Fire Code in 2013. Some Town Council guidance adds that where a corridor is narrower than the required clear width, no objects should be placed in it at all. Combustible storage such as cardboard, old furniture and piles of newspapers is not permitted.
Why the width matters
A 1.2-metre clear passage allows two people to pass, or a resident to be helped or carried out, and lets firefighters move hoses and equipment along the corridor. Items that are harmless on a normal day, such as a bicycle, a cabinet or a row of large planters, can become obstacles in smoke and darkness and can add fuel to a fire.
Who enforces the rules
The HDB corridor is common property managed by the Town Council. Under the Town Councils Act, Town Councils make by-laws to regulate the use of common property, including the placing of objects in common areas, and these by-laws are typically guided by SCDF’s guidelines. Town Councils can remove and detain obstructing items after giving notice. SCDF, for its part, can issue Fire Hazard Abatement Notices requiring Town Councils or management corporations to rectify fire hazards found during inspections. Penalties and procedures vary between Town Councils, so residents should check their own Town Council’s by-laws.
Renovation and the corridor
Renovation works sometimes affect the corridor directly. Common examples include replacing a main door or gate, changing windows that face the corridor, and installing items on the external wall. A few principles apply:
- Works are generally confined to the flat; the corridor itself is common property and cannot be enclosed, extended into or permanently fitted out by residents.
- A fire-rated entrance door should only be replaced with a door of the appropriate approved fire rating, and the closer must be retained.
- Renovation materials and debris must not be stored in the corridor or staircase, even temporarily, beyond what the Town Council permits.
- HDB’s renovation guidelines and permit requirements apply; our guide to the HDB renovation permit explains when approval is needed.
A shared space worth getting right
The best HDB corridors balance neighbourliness and safety. A tidy shoe rack and a few plants, set against the flat’s own wall and well clear of the parapet, keep the space personal without compromising the escape route. Overcrowding, hoarding and bulky storage do the opposite. Together with the void deck below, the corridor is part of the shared architecture that makes HDB estates work, and keeping it clear is part of keeping the whole block safe.
Frequently asked questions
Can I put a shoe rack in my HDB corridor?
Yes, SCDF allows shoe racks used solely for shoes, provided a clear escape passage of at least 1.2 metres is maintained from the parapet wall to the rack, and subject to your Town Council’s by-laws.
Are potted plants allowed along HDB corridors?
Only if the Town Council permits them and the corridor keeps an unobstructed width of at least 1.2 metres throughout, and plants should never be placed on the parapet wall or in staircases.
Why must the HDB corridor stay clear?
The corridor is part of the fire escape route from each flat to the staircases, so obstructions and combustible items can slow evacuation, hinder firefighters and help a fire spread.
Can I remove the door closer on my HDB main door?
No. Where an HDB flat has a fire-rated entrance door, the self-closing door closer is a safety device that must not be removed, because it keeps fire and smoke inside the flat and out of the corridor.
Who do I contact about items blocking my corridor?
The Town Council manages common corridors and enforces its by-laws on obstructions, and SCDF can be approached about serious fire hazards in common areas.
Can I park my bicycle or PMD in the HDB corridor?
Generally no. Bicycles, personal mobility devices and other bulky items are not among the items SCDF’s guidelines allow in common corridors, and they can obstruct the escape route. PMDs carry an added fire risk from their lithium-ion batteries, so they should not be charged in the corridor. Use bicycle racks at the void deck or keep them inside the flat.
Can I install a CCTV camera outside my HDB flat?
Many residents install a camera at or near their main door, but you should follow HDB’s current guidelines and your Town Council’s rules on fixtures in common areas. Cameras should be positioned to cover your own doorway rather than a neighbour’s unit, and cabling must not be run across the corridor. Check the latest HDB guidance before installation.
Can I put up festive decorations in the HDB corridor?
Temporary festive decorations are usually tolerated, provided they do not narrow the 1.2-metre clear escape route, are not hung from the parapet wall, and do not add significant combustible material near the door. Lights should be designed for outdoor use and connected safely. Remove decorations after the festive period, and check your Town Council’s by-laws.
Related reading
- Home Improvement Programme HDB Guide: How HIP Works
- HDB Flat Types Explained: From 2-Room Flexi to 3Gen
- BTO Flat Explained: How Singapore’s Build-To-Order Works
- Strata Title Singapore: Ownership, MCSTs and Common Property
Planning works that affect your flat’s entrance, walls or structure? Talk to our consultancy or get in touch.